How to choose the right industrial heating cables

What is a heating cable

The different types of heating cable each have their own advantages and disadvantages.

Which cable you should choose depends entirely on your application.

Heating cables are designed for a wide range of industrial, commercial and residential applications. There is a large variety of cable technologies – including self-regulating, constant-watt, mineral-insulated and series-resistance types.

Different types of heating cables:

So which type should you choose?

It depends on whether you need them for process temperature maintenance, freeze protection, flow assurance, domestic hot water temperature maintenance, snow melting, gutters or underfloor heating.

Below is an overview of the three most commonly used cable types.

Mineral-insulated heating cables

These heating cables are commonly referred to as MI heating cables.

The MI cable is typically used where very high temperatures are required and where traditional heating cables are not suitable. The MI cable can withstand temperatures up to 700°C, as its construction uses magnesium oxide, which is also known from tubular heating elements. They can withstand most types of chemicals and have very high mechanical stability due to the outer sheath, which is made of either stainless steel or alloy.

The MI cable must be sized very precisely, as it is not possible to cut this cable type to length. MI cables can be manufactured from very short lengths, approx. 30 cm, up to several kilometres.

MI cables are used for heating pipes, as this cable type can be produced with very high output. Other applications include bitumen production and condensation protection of filter systems.

Constant-watt heating cables

Constant-watt cables have been produced for more than 30 years and, as the name indicates, these cables deliver the same output regardless of the pipes they are installed on. These heating cables can be used for a wide range of applications, including temperature maintenance in pipes and tanks, and as underfloor heating cables.

The constant-watt cable is constructed in zones, typically between 0.5 and 1 m long. This depends on the output and voltage the cable is designed for. When terminating the cable, you must be aware of these zones, as the first section of the cable can be made as a cold lead with no output.

Sizing of the heating cable must be carried out by technically competent personnel, as there are many different solutions in terms of voltage, output, outer sheath material and classifications.

Self-regulating heating cables

Self-regulating heating cables are the most widely used heating cables in the world. Polymer technology has been continuously developed, so manufacturers worldwide can now offer cables with very high technical performance compared with similar electric heating products.

Self-regulating heating cables can be used in many applications, including freeze protection of pipes and tanks, temperature maintenance, heating of roads, ramps and pavements, as well as gutters.

A clear advantage of self-regulating heating cables is that the installer can cut them to length on site.

They also regulate the output themselves in relation to the surroundings. They will therefore always deliver a small output according to the temperature curve that suits the individual cable.

Termination of the self-regulating heating cable is typically done using complete termination kits or directly in a junction box.

5 things you need to have in place when choosing heating cables:

1. Know your requirements

Do you need to heat, maintain a temperature, or provide freeze protection?

2. Clarification

Clarify whether there is anything that can dissipate heat from the cable, e.g. pipe supports (which dissipate directly), pumps and motors (which require additional heating).

3. ATEX

Is it an ATEX area, or a “Safe Area”?

4. Practicalities

You need to have the practical details under control:

  • On-site insulation
  • Aluminium tape
  • Number of installation kits
  • Junction boxes
  • Fuse sizing.

5. Distance

Measure the distance to the supply point.

Conclusion

Sizing the right heating cable is the most important parameter for service life and for ensuring that the product in the pipes or tank reaches the correct temperature.

Installation of the heating cable must be carried out by instructed personnel in cooperation with the supplier, who understands the importance of a reliable installation.

Wide range of heating cables