Why the energy demand differs so widely
When working with heating cables in industry, it is important to distinguish between two completely different functions: heating a system from a cold state and temperature maintenance of an already warm system.
At first glance, it may seem like the same thing – but the difference in energy demand is enormous.
Why does heating require so much more energy?
Heating means that the entire mass in a pipe or tank must be brought from one temperature to another. This applies both to the medium itself (water, oil, chemicals) and to the surrounding material – pipe walls, tanks, valves, and other equipment.
With temperature maintenance, the situation is completely different. Here, the system is already warm, and the heating cables only need to compensate for the heat loss escaping through the insulation.
That is why we say:
- Heating = raise the energy content of the entire system
- Maintenance = balance the heat loss
1,000-litre water tank heated to 60°C
Let us take a hypothetical example with a 1,000-litre water tank.
- The temperature in the tank starts at 10°C.
- It must be heated to 60°C.
- The density of water is approx. 1,000 kg/m³, and the specific heat capacity is 4.18 kJ/kg·K.
To raise the water by 50°C requires:
Q = 1,000 kg × 4.18 kJ/kg·K × 50 K = 209,000 kJ ≈ 58 kWh
So, 58 kWh is required just to raise the temperature.
Once the tank is at 60°C, the requirement for temperature maintenance is much lower. Here, only energy corresponding to the heat loss through the insulation needs to be supplied – perhaps 2–3 kWh per day, depending on the surroundings and insulation thickness.
The example clearly shows why the heating phase requires much higher power and energy than the subsequent maintenance.
Heating cables for heating and maintenance
This difference is also reflected in the choice of heating cables and control:
- For heating, cables or systems with high output are often used. This may be self-regulating heating cables, or in some cases heavy-duty resistance cables that can deliver the required energy to bring the temperature up quickly.
- For temperature maintenance, self-regulating heating cables are often ideal. They adjust output to the surroundings and ensure that only the energy necessary to keep the temperature stable is used.
At Newtronic, we always assess the requirement in collaboration with the customer. In some projects, this calls for a combination – a more powerful solution for the heating phase and a more energy-efficient solution for day-to-day maintenance.
Why is the difference important for the design?
If you try to use the same system for both functions without distinguishing between them, you risk two things:
- Undersizing – the system cannot deliver the energy required for heating, and the process is delayed or fails.
- Oversizing – the system adds too much energy during the maintenance phase, which can result in unstable operation
That is why we always size with higher output for heating and lower, more precise output for maintenance.
Heating vs. temperature maintenance – industry examples
- Food industry: Syrup and chocolate first require heating to the right consistency, but afterwards they only need to be kept at temperature to be pumpable.
- Pharma: Solutions must be brought up to a specific process temperature, but afterwards it is critical to maintain a very stable maintenance temperature.
- Heavy industry: Oil and lubricants must be heated to be able to flow, but once they are running in the system, the maintenance requirement is far lower.
These examples show that understanding the difference between heating and temperature maintenance is central in almost all industries.
Energy consumption and sustainability
At a time when energy prices and CO₂ emissions matter more than ever, it is an advantage to separate the two phases.
- Heating requires more energy, but often happens less frequently.
- Maintenance is day-to-day operation – and this is where the great potential for energy savings lies.
With correct sizing and control, heating cables can contribute to both lower energy costs and greener operation.
Newtronic helps you find the right balance
At Newtronic, we size heating cable systems with a focus on both needs. We analyse how much output is required for heating and how much is needed for maintenance – and we ensure that the system always has the necessary safety factor without wasting energy.
Would you like to know how your plant should be sized for both heating and temperature maintenance? Contact us – we will help you find the optimal solution.