High-temperature cable

Custom duct heater for industrial process air

Heating cables for special applications

High-temperature cable is used for heat tracing where standard heating cables are not sufficient due to high temperatures, long circuit lengths or demanding process conditions.

At Newtronic, we advise on selecting and sizing high-temperature cables for pipes, tanks, valves, flanges and process equipment. We help assess temperature requirements, medium, insulation, installation, control and documentation, so the solution fits the specific industrial application.

Mineralisoleret varmekabel med kappe af ALLOY

High-temperature cable for demanding heat-tracing tasks  

High-temperature cable is used in industrial plants where heat tracing is needed at temperatures or operating conditions that place higher demands than standard freeze protection. This may include process pipes, tanks, valves, flanges, instrumentation or technical equipment where the medium must be kept warm, liquid or process-ready.

In many applications, high-temperature heat tracing is about temperature maintenance. Here, the heating cable must not only protect against frost, but ensure that the medium does not solidify, crystallise, become too viscous or lose its desired properties. This may, for example, be in processes with oil, bitumen, wax, chemical media, sugar-containing liquids or other products where temperature drops can cause blockages, deposits or unstable operation.

High-temperature cables are also used when the installation has long pipe runs, high ambient temperatures or requirements for robustness in demanding environments. Here, it is important to choose the cable type based on the entire installation and not only on the desired temperature.

When standard heating cables are not enough

A self-regulating heating cable is often suitable for freeze protection and standard temperature maintenance. At higher temperatures, long circuit lengths or special process requirements, it may be necessary to choose a different cable type.

High-temperature cables can, among other things, be resistance heating cables, series-resistance heating cables or mineral-insulated heating cables. The choice depends on the application, temperature, heating circuit length, voltage level, material requirements and the mechanical conditions around the installation.

Mineral-insulated heating cables are particularly relevant in environments with high requirements for temperature resistance, mechanical strength and long service life. They can be used on pipes, tanks, valves and fittings where the solution must withstand demanding operating conditions. Series-resistance cables may be relevant for long circuit lengths where the output must be adapted to the overall circuit and the installation design.

Temperature maintenance in critical processes

In process plants, even small temperature drops can have major consequences. If a medium starts to crystallise, solidify or become too viscous, it can affect flow, dosing, product quality and reliability. That is why high-temperature cable is often an important part of plants where a stable temperature is necessary to keep the process running.

This applies, among other things, in food production, the chemical industry, energy, offshore, maritime installations and other process environments where pipes and components must be kept at a controlled temperature. In these plants, the cable, insulation, sensor placement and control must be sized as a complete system so the temperature is maintained throughout the relevant part of the installation.

Newtronic helps clarify what temperature actually needs to be maintained and which conditions affect heat loss. This may include pipe diameter, insulation thickness, ambient temperature, wind exposure, the properties of the medium, start-up situations and response-time requirements.

Sizing requires the right process data

A high-temperature cable must be sized based on specific data. It is not enough to know the desired temperature. We also look at the medium, pipe material, pipe diameter, insulation, circuit length, voltage, installation conditions, temperature class, safety requirements and documentation needs.

At high temperatures, material selection and installation become especially important. The cable type, sheath, accessories, connection and fastening must withstand the temperatures and influences the installation is exposed to. At the same time, the control system must ensure the temperature is kept stable without unnecessary energy consumption or risk of overheating.

At Newtronic, we size high-temperature cables as part of a complete heat-tracing solution. This means we assess the heating cable, control, accessories, insulation and documentation before the solution is specified.

Control and monitoring of high-temperature heat tracing

With high-temperature heat tracing, control is a central part of the solution. Many installations require more than simple on/off switching, especially if the temperature must be kept within a narrow range or if the system is part of a critical process.

The control can include temperature sensors, controllers, thermostats, control panels, alarm outputs and monitoring of multiple heating circuits. In larger plants, integration with the existing automation system may be needed so operations staff can get an overview of temperatures, faults and status.

Correct control makes the solution more reliable and easier to service. This is especially important in plants where insufficient temperature maintenance can lead to production stoppages or difficult cleaning and maintenance tasks.

High-temperature cables in ATEX and demanding environments

High-temperature cables are often used in environments with stricter requirements for safety, documentation and installation. This may include areas with chemical exposure, moisture, outdoor installation, high process requirements or ATEX-classified zones.

In ATEX areas, the entire solution must be assessed as a whole. Cable type, temperature limitation, control, accessories, insulation, installation and documentation must match the specific zone, temperature class and installation. This requires a technical assessment early in the project so the solution can be engineered correctly from the start.

Get advice on high-temperature cable

Do you need high-temperature cable for heat tracing, temperature maintenance or process heating? Contact Newtronic for technical advice and project engineering.

We help clarify the application, select the correct cable type and size a solution where heating cable, control, accessories and documentation match the plant’s temperature requirements, environment and operation.

Custom duct heater for industrial process air
TESH TM kabel med kobberleder og skærm i tværsnit

FAQ

An MI cable is a mineral-insulated heating cable with a robust metal sheath and is typically used where temperatures are very high, power output is high, or mechanical and chemical conditions are demanding. A series-resistance cable such as TESH is primarily used for longer heating circuits where a standard parallel-connected heating cable is not suitable. The choice therefore depends, among other things, on temperature, circuit length, required power, environment, and installation conditions.

It depends on the cable type. Mineral-insulated MIQ cables can be sized for temperature maintenance up to 500°C and can withstand continuous temperature exposure up to 600°C when the cable is not energised. Series-resistive TESH cables can withstand temperature exposure up to 260°C when de-energised. The permissible temperature always depends on the specific cable type, output, and installation.

A self-regulating heating cable is often the simplest solution for freeze protection and standard temperature maintenance. High-temperature cables become relevant when the process temperature is higher, when the cable is exposed to high temperature from the process, or when long circuit lengths or higher power density are required. The cable type should therefore be selected based on both normal operation and the maximum temperature the installation may be exposed to.

Yes. Series-resistive heating cables are particularly suitable when the circuit length exceeds what is possible with parallel heating cables. Mineral-insulated MIQ systems can, in certain configurations, be designed for pipeline runs of up to approx. 1.6 km from a single supply point. However, the achievable length depends on voltage, resistance, the required output, and the specific sizing.

Yes, provided a cable is selected that is designed for that temperature exposure. For example, TESH is developed for installations where the heating cable is exposed to the elevated temperatures that may occur during steam purging. During design, the temperature during both normal operation and cleaning or process shutdown must therefore be taken into account.

Newtronic leverer komplette løsninger
– fra professionel rådgivning og projektering til installation og idriftsættelse.

Certifikater

Vores løsninger lever op til de standarder, din branche kræver.
Norsok
NORSOK-compliant solutions
Solutions tailored to the requirements of the Norwegian offshore industry
ATEX marking for explosive atmospheres
ATEX-approved solutions
Approvals for explosive atmospheres in the EU
IECEx
IECEx-certified
International certification for hazardous areas
Newtronic is food-approved
Food-approved
Solutions for hygiene- and process-critical environments
CE mark for EU conformity
CE
CE-marked products for the European market
DNV certification
DNV
Approvals for marine and offshore applications
Lloyd’s certified
Lloyd’s Register
Type approvals for marine and offshore
UL and CSA certification logos
UL / CSA
Approvals for the North American market

Kontakt os og få
hjælp og rådgivning