Accessories for reliable heat tracing
Accessories for heating cables are an important part of a reliable heat tracing installation. This includes, among other things, power connection kits, end termination kits, splice kits, tape, cable glands, band clamps, warning labels and mechanical protection.
At Newtronic, we supply heating cable accessories as part of the complete solution, ensuring that the cable, installation and documentation match the installation. We help you select the right components based on cable type, pipe diameter, environment, insulation, temperature requirements and any requirements for EX areas.
Junction boxes
Uncategorized
PETK – End termination kit for plastic junction boxes
PETK
The following kits are used for connecting plastic junction boxes:
The PETK kits must be used to insulate the conductors and seal the heating cable watertight.
PETK-1 BSX, RSX, VSX
PETK-2 HTSX, KSX
The kits include
- RTV sealing adhesive
- Boot for conductors
- End cap
- Tape (PETK-3 only)
- End termination warning label
- Gasket (PETK-3 only)
- Yellow/green sleeve for marking the screen
SCTK – Power connection kit over insulation
For connection over insulation of splice box, type ZS, and end-of-line box with light indication, type ZE-B, the following kits are used:
SCTK-1 BSX, RSX, VSX
SCTK-2 HTSX, KSX
The kits include
- 2 pcs. short boot pieces
- 2 pcs. small crimp connectors
- 1 pc. large crimp connector
- 2 pcs. insulation for small crimp connector
- 1 pc. insulating cap
- 1 pc. yellow/green hose
- 1 pc. RTV sealing adhesive
- 1 pc. gasket for HPT cable
Aluminium tape
For securing heating cable to pipes or equipment.
AL-20H
Max. operating temperature 150o C
Min. installation temperature -5o C
Dimensions 50 mm x 55 m
Installed along the cable
Estimated consumption per m of pipe = 105% of the pipe length in m
AL-30H
AL-30H: width 76 mm
IEK – Insulation entry kit
The insulation entry kit IEK is used to route the heating cable out through the insulation jacket.
The kit consists of:
Stainless plate in 304 steel, 60 x 60 mm
Plastic cable gland for heating cable
M25 brass locknut
Type Used for
IEK-14 HTSX, KSX
IEK-18 HPT, KSR
IEK-19 BSX, FLX
IEK-20 VSX, RSX
IEK-TES LT TESH, PT-100
Fibreglass tape
For securing heating cable to pipes
FT-1H 33
Max. operating temperature 260o C
Min. installation temperature -40oC
Dimensions 12 mm x 33 m
Installed around the pipe approximately every 300 mm
Estimated consumption per m of pipe = 3.5% of the pipe diameter in mm
Cable glands
Plastic cable glands
Polyamide cable glands with flat-hole gaskets for heating cables.
The cable glands are approved for use in industrial and EX-classified areas in accordance with ATEX/IECEx.
Protection rating IP66/IP68.
Type Used for
M25-14-EXE HTSX, KSX
M25-18-EXE HPT, KSR
M25-19-EXE BSX, FLX
M25-20-EXE VSX, RSX
M25-EXE Supply cable, Ø 7-17 mm
M20-EXE Supply cable, Ø 4-13 mm
Warning label
Warning labels are fitted on the outside of the jacket on insulated pipes to indicate that a heating cable is installed beneath the insulation.
The labels are available in various languages – the most common languages are listed below – for others, please contact us.
Type Language
CL-DK Danish
CL-SE Swedish
CL-UK English
Labels for identifying terminations and splices under insulation are included in Thermon’s PETK kit.
Armoured conduit kit
Item number: 001748
The kit consists of:
1.5 m armoured conduit SS316 P40
2 pcs. cable gland M25
1 pc. insulation entry plate
1 pc. nut M25
Band clamp
Band clamps are used to secure pipe-mounted junction boxes to the pipe.
Band clamps are available in 3 sizes.
Type Length (mm) used on pipes Ø up to
B-4 580 4” / DN100
B-10 1000 10”/ DN250
B-21 1600 20”/ DN500
Band clamps can be joined if necessary to increase the length.
SK-SX-EX – Splice kit under insulation in a hazardous area
SK-SX-EX is used for splicing Thermon’s self-regulating heating cables under the insulation in a hazardous area.
The kit consists of stainless-steel half shells assembled with screws, gaskets for self-regulating heating cables, RTV sealing compound, insulation tape, and the necessary crimp connectors.
JB-K-0-4 – Wall-mounted enclosure, IP65
Junction box in polystyrene for use in industrial environments, both indoors and outdoors. The box can be mounted on a wall or cable ladder and is IP65-rated.
Technical specifications
- Dimensions: 126 × 126 × 95 mm
- Max. voltage: 550 V
- Material: Polystyrene
- Temperature range: -20 °C to +90 °C
- Cable entries: 4 × M25 threaded
- Protection class: IP65
- Terminals: 4 × 6 mm² + 2 × 6 mm² PE
- Mounting: Wall or cable ladder
- Application: Industrial environments, indoors and outdoors
- Type: JB-K-0-4xM25-IND
EX wall-mounted junction box, IP65
Junction box for use in industrial environments and EX-classified areas. The box is intended for mounting on a wall or cable ladder and is made of non-metallic composite.
Technical specifications
- Dimensions: 126 × 126 × 95 mm
- Max. voltage: 750 V
- Material: non-metallic composite
- Temperature range: -25 °C to +90 °C
- Cable entries: 4 × M25 threaded
- Protection rating: IP65
- Terminals: 4 × 6 mm² + 2 × 6 mm² PE
- Mounting: wall or cable ladder
- Application: industrial and EX-classified areas
- Type: JB-K-0-M25-EX
JB-K/XP – Pipe-mounted junction box
For use in industrial environments, indoors and outdoors.
Mounted directly on the pipe – up to 3 heating cables can be routed out through the insulation entry kit base.
Polystyrene junction box for connecting heating cables. The box is IP65-rated and suitable for operating temperatures from -20°C to +90°C.
Technical specifications
- Dimensions: 126 × 126 × 95 mm
- Max. voltage: 550 V
- Material: Polystyrene
- Temperature range: -20°C to +90°C
- Cable entries: 2 × M25 thread, plus the option of routing up to 3 heating cables through the base
- Protection class: IP65
- Terminals: 4 × 6 mm² + 2 × 6 mm² PE
- Type: JB-K/XP-PLUS-IND
ZP-XP – Pipe-mounted composite box, IP66
Junction box for use in industrial environments and EX-classified areas. The box is mounted directly on pipes and allows up to 3 heating cables to be routed through the insulation entry base.
Technical specifications
- Dimensions: Ø 155 × D 190 × H 200 mm
- Max. voltage: 750 V
- Material: Non-metallic composite
- Temperature range: -60 °C to +55 °C
- Max. pipe temperature: 250 °C
- Cable entries: 2 × M25 threaded, with the option to route up to 3 heating cables through the base
- Protection rating: IP66
- Terminals: 4 × 6 mm² + 2 × 6 mm² PE
- Mounting: Directly on pipes
- Application: Industrial and EX-classified areas
- Type: ZP-XP
ZE-Beacon – Termination above insulation with LED indication
The Terminator™ ZE-Beacon is a mechanical termination for mounting above the insulation with integrated LED indication, showing whether the installed heating cable is energized. The ZE-Beacon is available with either green or red LED indication.
Technical specifications
- Dimensions: Ø 89 × H 210 mm
- Max. voltage: 600 V
- Supply voltage: 110–277 VAC
- Material: Non-metallic composite
- Temperature range: -60 °C to +45 °C
- Max. pipe temperature: 250 °C
- Cable entry: Accommodates 1 heating cable through the base
- Protection rating: IP66
- Temperature class: T6
- LED indication: Green or red
Content
- Insulation entry kit base with gasket for 1 heating cable, plus pressure plate with O-ring
- Transparent top cover
- Guide for band clamp
- Band clamp for pipes up to 4″
- LED module
Note: Power connection kit SCTK must be ordered separately.
ZS – Termination over insulation
Terminator™ ZS is a non-metallic mechanical termination designed for installation over the insulation. The solution is developed for quick and easy termination of heating cables and can accommodate up to 3 heating cables through the insulation entry kit base.
Technical specifications
- Dimensions: Ø 75 × H 200 mm
- Max. voltage: 600 V
- Material: Non-metallic composite
- Temperature range: -60 °C to +55 °C
- Max. pipe temperature: 250 °C
- Cable entries: Up to 3 heating cables through the base
- Protection rating: IP66
Content
- Insulation entry kit base with gasket for up to 3 heating cables, plus pressure plate with O-ring
- Top cover
- Guide for band clamp
- Band clamp for pipes up to 4″
Note: PETK end termination kit is ordered separately.
ZS – Splicing or T-splice over insulation
Terminator™ ZS is a mechanical solution for splicing heating cables or performing a T-splice over the insulation. The solution is mounted directly on the pipe and allows entry of up to 3 heating cables through the insulation entry kit base.
Technical specifications
- Dimensions: Ø 75 × H 200 mm
- Max. voltage: 600 V
- Material: Non-metallic composite
- Temperature range: -60 °C to +55 °C
- Max. pipe temperature: 250 °C
- Cable entries: Up to 3 heating cables through the base
- Protection class: IP66
- Application: Splicing or T-splice of heating cables over insulation
Content
- Insulation entry kit base with gasket for up to 3 heating cables, plus pressure washer with O-ring
- Top cover
- Guide for band clamp
- Band clamp for pipes up to 4″
Note: Power connection kit SCTK is ordered separately.
EX wall-mounted stainless steel junction box
Stainless steel AISI 316L junction box for wall mounting in industrial environments.
The box is designed for high corrosion resistance and is suitable for Ex e applications.
Technical specifications
- Type: Junction Box S/S 316L WM Exe
- Dimensions: 150 × 150 × 81 mm
- Max. voltage: 690 V
- Material: Stainless steel AISI 316L
- Temperature range: -55 °C to +70 °C
- Cable entries: 4 × Ø25 mm
- Protection class: IP66
- Terminals: 4 × 6 mm² + 2 × 6 mm² PE
- Mounting: Wall mounting
- Application: Industrial and Ex e-classified areas
- Type: 001786
Downloads
Accessories that ensure correct installation of heating cables
Heating cable accessories have a major impact on whether a heat tracing installation works correctly in practice. A heating cable may be correctly sized, but if connection, termination, fastening or entry is not carried out correctly, it can affect reliability, service life and service access.
That is why accessories are not just extra components. They are part of the heating cable system itself. The accessories must match the cable type, pipe routing, insulation and the environment in which the installation is located. This applies to both freeze protection, temperature maintenance and more demanding industrial heat tracing solutions.
At Newtronic, we help put together the right heating cable accessories so the installation can be carried out correctly from the start.
Power connection kits and end termination kits
Power connection kits are used where the heating cable must be connected to the power supply or a junction box. End termination kits are used at the end of the heating circuit, where the cable must be sealed and protected correctly.
These components are crucial for a tight, safe and durable installation. They must be selected according to cable type and installation conditions so the conductors are correctly insulated and the heating cable is protected against moisture, mechanical impact and incorrect installation.
Newtronic supplies, among other things, power connection kits and end termination kits for different types of heating cables, ensuring the components match the specific heat tracing solution.
Splice kits and joints
In some installations, there is a need to splice or join heating cables. This may be for repairs, circuit adjustments, or installations where the cable routing requires a joint.
Splice kits must be selected and installed correctly so the joint is electrically safe, mechanically stable and suitable for the environment in which it is installed. This is especially important in industrial plants, where the installation may be exposed to moisture, vibrations, temperature fluctuations or chemical exposure.
For projects with many circuits or complex pipe routing, we help clarify where joints should be placed and which components are suitable for the task.
Tape, band clamps and fastening
Heating cables must be correctly fastened to pipes, tanks, valves or other equipment. For this, fibreglass tape, aluminium tape, band clamps or other installation components are typically used, depending on cable type, temperature and substrate.
Fastening affects heat transfer between the cable and the pipe. If the cable does not lie correctly against the surface, the output may be used less effectively and the temperature may become uneven. In some installations, aluminium tape may be relevant where improved heat distribution or more stable contact between the cable and the surface is required.
The choice depends on temperature, pipe material, insulation, installation conditions and the requirements of the specific installation.
Cable glands and insulation entry kits
When heating cables are routed through insulation, cladding or into boxes, the entry must be carried out correctly. Cable glands and insulation entry kits protect the cable and help ensure a tight and robust transition.
This is important in installations where moisture, dust, outdoor environments or mechanical impact can reduce service life. Correct entries also make the installation more service-friendly and reduce the risk of errors during later access to the plant.
In EX areas, cable glands, entries and other accessories must be assessed as part of the overall installation. Here, components, installation and documentation must match the zone classification and the specific project requirements.
Warning labels and marking
Heat tracing installations should be clearly marked so operations, service and maintenance can see that there is a heating cable under the insulation. Warning labels are typically fitted on the outside of the insulation cladding and make the installation easier to understand during inspection and service.
Correct marking reduces the risk of heating cables being damaged during work on pipes, flanges, valves or insulation. This is especially relevant in larger plants where many pipe runs and technical installations are located close together.
Mechanical protection for exposed installations
In some plants, heating cables are particularly exposed. This may be at flanges, valves, insulation terminations, entries or areas with a risk of impact, wear or service work close to the cable.
In such cases, mechanical protection may be necessary to extend service life and reduce the risk of cable damage. This may, for example, be protective sleeves, covers, plates or custom-made parts that protect the heating cable at exposed points.
Newtronic helps assess where mechanical protection should be included in the installation so the solution is practical to install and robust in operation.
Heating cable accessories from Thermon
Newtronic supplies heating cable accessories from Thermon, which offers a broad range of system accessories for heat tracing. This includes, among other things, connection, termination, splicing, fastening, marking and entries for different cable types and installation environments.
This makes it possible to put together a solution where the heating cable and accessories match from the start. This is important for installation, operation, documentation and later service.
Get help choosing heating cable accessories
Do you need heating cable accessories, or are you unsure which components fit your installation? Contact Newtronic for technical advice.
We help select the right accessories based on cable type, pipe routing, insulation, temperature, environment and documentation requirements, so the heat tracing installation can be carried out correctly and reliably.
See heating cable accessories in our Techcenter
Visit our Techcenter and get a practical walkthrough of heating cable accessories—from connections and terminations to installation and temperature control.
We base our advice on your project and advise on which components match the heating cable, the installation and the operating conditions. Here you can see the solutions up close and clarify questions about selection and installation before the project is launched.
Contact us to arrange a visit with a demonstration and technical sparring.
Products you may also be interested in
FAQ
It depends on the cable type and the installation. A complete heat tracing system typically requires a power connection kit and an end termination kit, as well as installation materials such as aluminium tape, band clamp and warning labels. For branches or joints, splice kit and junction boxes may also be required. The accessories must be compatible with the selected heating cable and should be chosen based on factors such as pipe diameter, temperature, environment and any ATEX requirements.