Control of heating cables

Control of heating cables for reliable heat tracing

Control of heating cables is essential for a reliable heat tracing solution. The right control ensures that the heating cables operate only when heat is needed, and that pipes, tanks, valves, or process equipment are kept at the desired temperature.

At Newtronic, we provide advice on the control, regulation, and monitoring of heating cables for industrial plants. We help with everything from simple thermostat solutions to more advanced systems with temperature sensors, alarms, circuit monitoring, control panels, and integration with the customer’s automation system.

Temperaturstyring med display, der viser 42 °C, fra Thermon EXO Touch

Complete panels with
Genesis controller

Newtronic supplies customised control panels for controlling and monitoring industrial heating cable systems. The panels can be built from simple solutions with a few heating circuits to larger systems with individual temperature control, monitoring, and alarms.

The solution is sized based on the heating cables’ output, number of circuits, control requirements, and requirements for communication with higher-level PLC or SCADA systems.

Genesis Controller™ Procesopvarmning, herunder elektriske varmekabelsystemer

Correct control makes heating cables more reliable

Control of heating cables is an important part of any heat tracing solution. The heating cable itself must be correctly sized, but without the right control the installation can become less efficient, harder to monitor, and more prone to faults.

In many plants, heating cables are used for freeze protection. Here, the control must ensure that the pipes are kept frost-free when the temperature drops, without the plant using unnecessary energy during periods when heat is not needed. This may be relevant for outdoor pipework, water pipes, sprinkler systems, instrument tubing, valves, and technical installations where frost can lead to downtime or damage.

In other plants, heating cables are used for temperature maintenance. Here, the control must ensure that a medium is maintained at a specific temperature throughout the process. This can be critical for media that can crystallise, solidify, condense, become too viscous, or lose the desired process properties if the temperature drops.

From simple thermostat to advanced monitoring

The choice of control depends on the installation’s size, criticality, and temperature requirements. For smaller plants, a simple thermostat may be sufficient. Here, the temperature is typically measured on the pipe, surface, or ambient environment, and the heating cable is switched on and off as needed.

For larger or more critical plants, more advanced control and monitoring may be required. This can include multiple heating circuits, individual temperature measurements, alarm outputs, fault logging, display of operating status, and the option for communication to a supervisory control system, PLC, or SCADA.

Newtronic helps select the control solution that matches the plant’s function. The goal is not to make the control more advanced than necessary, but to ensure the right balance between reliability, overview, energy consumption, and documentation.

Control for freeze protection

For freeze protection, the purpose is typically to keep the installation above freezing. It sounds simple, but the control still needs to be selected correctly. There may be differences in whether the temperature should be measured on the pipe, in the ambient environment, or at a specific critical point on the installation.

If the control responds only to air temperature, there may be situations where the pipe is colder or warmer than the surroundings. If the control measures directly on the pipe, you get a more specific measurement of the installation’s temperature. The right solution depends on the pipe routing, insulation, location, medium, and operating pattern.

We advise on sensor placement, thermostat selection, and circuit segmentation, so that freeze protection operates reliably and is practical to service.

Control for temperature maintenance

For temperature maintenance, the requirements are often higher than for standard freeze protection. Here, it is not only about preventing frost, but about maintaining a specific process temperature.

This may be in pipework with sugar-containing liquids, syrup, oil, fats, chemical media, or other products where temperature has a direct impact on flow, dosing, quality, or process stability. If the temperature drops too much, it can cause deposits, blockages, or unstable operation.

In these plants, it is important that the control is sized together with the heating cable. Temperature sensors, control method, setpoints, alarm limits, and circuit segmentation must be aligned with the medium’s properties and the plant’s operation.

Monitoring and alarms provide a better overview

In larger heat tracing systems, monitoring can be an important part of the solution. When there are many heating circuits, it is not always enough to know that the system is on. Operations staff often need an overview of temperatures, faults, alarms, and the status of each circuit.

Monitoring can make it easier to detect faults before they develop into downtime. This may include, for example, lack of heat, sensor faults, temperature deviation, tripped circuits, or other conditions that require action.

Newtronic supplies control and monitoring as part of the complete heat tracing solution. This may be relevant in the process industry, food production, pharma, energy, data centres, offshore, and other plants where temperature and uptime are critical.

Control in ATEX and demanding environments

In ATEX areas and other demanding environments, control of heating cables must be assessed as part of the overall installation. This includes, among other things, temperature limiting, sensor placement, component selection, documentation, and the relationship between cable, insulation, and control.

It is not enough to select a single component based on a zone classification. The entire solution must match the installation’s environment, temperature class, and safety requirements. Therefore, we recommend that control and documentation are considered early in the project.

Get advice on controlling heating cables

Do you need control of heating cables for freeze protection, temperature maintenance, or process-critical installations? Contact Newtronic for technical advice.

Terminator ECM - EX tilslutningsboks til varmekabler med en integreret elektronisk termostat.
Temperaturstyring med display, der viser 42 °C, fra Thermon EXO Touch
Genesis Duo har et 4,3" LCD-display med berøringsfunktion og en ekstra lysring til visuel indikation
Genesis Controller
Collaboration creates success

Most frequently
asked questions

It depends on what the heating cables are intended to ensure. For simple freeze protection, a thermostat is often sufficient. For temperature maintenance or process-critical installations, there may be a need for temperature sensors, individual control, alarms, and monitoring of the individual heating circuits.

Both are possible. Ambient temperature is often used for freeze protection, while measuring directly on the pipe provides better control of the installation’s actual temperature. The choice depends, among other things, on the medium, insulation, location, and how precisely the temperature must be maintained.

A thermostat is often suitable for smaller, straightforward heat tracing installations. With many heating circuits or critical processes, a controller or control panel can provide individual temperature control, alarm management, fault logging, and overall system monitoring.

Yes. Advanced control systems can, among other things, monitor temperature, load current, earth leakage current, sensor faults, and the status of each individual heating circuit. This makes it possible to detect operational issues earlier and gives operations staff a better overview of the installation.

Yes. Larger heating cable systems can be integrated with higher-level automation systems so that temperatures, alarms, and operating status can be monitored centrally. The communication solution depends on the selected controller and the system’s automation architecture.