Flanged immersion heaters for tanks, vessels and process plants
Custom flanged immersion heaters for industrial process heating
A flanged immersion heater is a reliable and efficient solution when liquids, gases or other process media need to be heated directly in a tank, vessel or process plant. The solution is widely used in industry where controlled temperature, high output and a design that matches the specific application are required.
At Newtronic, we do not supply flanged immersion heaters as standard components without technical clarification. Each flanged immersion heater is sized based on the process it will be part of. This means we assess the medium, temperature, pressure, volume, power requirement, installation conditions, material requirements, control and safety before specifying the solution.
Flanged immersion heaters can be used to heat, among other things, water, oil, thermal oil, chemical liquids, process liquids, air, gas, nitrogen, CO₂, hydrogen and aggressive media. Therefore, it is important that the heating element is adapted to both the medium’s properties and the operating conditions it must work under.
Designed for the medium, temperature and output
The right solution does not depend only on the desired output in kW. A flanged immersion heater must be sized according to the full specification. For liquids, it is important to assess heat transfer, circulation, risk of fouling, the medium’s viscosity and the permissible watt density on the heating elements.
For gas or air, flow, temperature rise, residence time and heat distribution must be assessed carefully. For aggressive media or high temperatures, there are specific requirements for materials, surfaces and safety.
Newtronic supplies custom flanged immersion heaters from smaller outputs to very large industrial solutions. We have delivered models up to 5.5 MW in a single unit, where the design, flange, heating elements, junction box and control are adapted to the specific process.
Materials for demanding process conditions
Material selection is crucial for both service life and operational reliability. Flanged immersion heaters can be manufactured in materials such as AISI 321, Incoloy 800 and Incoloy 825, depending on the medium, temperature, corrosion conditions and mechanical load. For specific media, special coatings can also be used to improve resistance to corrosion or fouling.
The right material choice always depends on the application. Therefore, information about the medium, temperature, concentration, pressure, flow or circulation, and any cleaning processes should be included early in the sizing process.
Flanged immersion heaters for tanks, vessels and process plants
A flanged immersion heater is often used directly in tanks and vessels, where the heating elements are inserted through a flange and transfer heat to the medium. This may be relevant for heating, temperature maintenance, preheating or process heating in industrial plants.
Flanged immersion heaters are also used in process plants, where the heat must be integrated as part of an overall solution. If the heating element is combined with a pressure vessel or a vessel, the solution will typically be specified as a circulation heater. This is relevant when the medium needs to be heated under flow, at higher pressure, or in a more closed and controlled process.
In this way, we can help select the right design from the outset, so the solution meets the process, installation and documentation requirements.
Control, safety and ATEX
A flanged immersion heater should always be considered together with the control and safety systems that must protect both the process and the plant. Depending on the task, the solution can be supplied with temperature sensors, safety thermostats, overtemperature protection, level protection, thermowells and junction boxes adapted to the installation environment.
For higher outputs, a control panel with contactors, SSR or power controllers is often recommended, so the output can be regulated correctly and gently. This provides better temperature stability and reduces the risk of unnecessary loads on the plant.
In ATEX areas, the entire solution must be assessed as a whole. This applies not only to the heating element itself, but also to temperature limiting, sensors, control, junction box, installation and documentation. Flanged immersion heaters can be designed for demanding environments, but the specific solution must always be aligned with the zone classification, temperature class and applicable requirements.
Contact an advisor about flanged immersion heaters
If you need a flanged immersion heater for a tank, vessel or industrial process, we can help clarify the right solution. Please send information about the medium, temperature, pressure, volume, desired output, material requirements, installation conditions and control requirements.
Related solutions
FAQ
Sizing is based on the medium, volume or flow, start and end temperature, required heat-up time, operating pressure, and heat loss. In addition, watt density, material selection, installation, and control must be assessed. Therefore, it is not only the required output in kW that determines the size of the flanged immersion heater.
Not necessarily. Different media impose different requirements for material, watt density and temperature. Oil typically requires a lower watt density than water, while chemical and aggressive media may require special materials or coatings. The flanged immersion heater should therefore always be specified for the specific medium.
A flanged immersion heater is typically relevant when the heating element must be installed directly in a tank or vessel and heat the medium there. A circulation heater is typically used when liquid or gas must be heated continuously under flow. The choice depends, among other things, on the medium, flow, temperature, pressure, and installation conditions.
Flanged immersion heaters can be sized from small industrial outputs to solutions of several megawatts. Newtronic can supply custom flanged immersion heaters up to 5.5 MW in a single unit. The achievable output depends, among other things, on the medium, voltage, the heating elements’ watt density, the flange, and the physical installation conditions.
Yes. Flanged immersion heaters can be engineered for demanding process conditions with both high temperatures and high pressure. Depending on the application, custom-designed solutions can be built for temperatures up to 800°C and pressures up to 90 bar. The specific limit depends on the medium, materials, flange, design, and applicable documentation requirements.