Electric steam boilers for flexible and efficient process steam
Electric steam boilers for industry and process plants
Electric steam boilers can be used as the primary steam source, as a supplement to an existing boiler plant, or as a decentralised supply for a defined process. Typical applications include cleaning, sterilisation, humidification, heating, food processing, and other industrial tasks where a stable and controlled steam supply is required.
At Newtronic, we base our recommendations on the process’s actual requirements. This includes steam capacity, operating pressure, steam quality, load profile, and the available electrical power.
Modular steam generators for varying steam demand
The compact electric steam generators are built in modules, making it possible to tailor capacity to each process. The range includes solutions with steam production from 10 to 320 kg per hour. Each module can be expanded to 160 kg per hour, and multiple steam generators can be connected in cascade for larger or fluctuating demand. A cascade solution can deliver up to 640 kg of steam per hour.
The modular design makes it possible to position the units according to the physical conditions in the plant room. This can be an advantage where space is limited, where access is through standard door openings, or when steam capacity needs to be expandable later. The compact construction reduces the footprint, and the modules can be arranged to suit the installation layout.
At low steam consumption, individual modules can be kept out of operation while the others follow the current demand. This provides a flexible solution for production where steam consumption changes throughout the day or between different process steps.
Fast steam close to the process
The modular steam generators can be ready for full steam production approximately three to five minutes after start-up. Capacity is continuously regulated according to steam demand, so the system does not necessarily have to run at maximum output all the time.
The fast start-up makes the solution relevant for processes with intermittent operation. The steam generator can be placed close to the point of use and started when the process requires steam. This can reduce the need to keep a larger central steam network warm during periods of limited consumption.
The system can be supplied with an integrated feedwater tank and feedwater pump. We also offer solutions with a combined water module that consolidates relevant components and simplifies installation. Depending on the configuration, the system can be prepared for automatic operation for up to 72 hours.
Control, monitoring, and remote support
Electric steam generators can be supplied with HMI operation, monitoring, and remote access. The operator can monitor steam pressure, water level, operating status, and alarms from the local interface. At the same time, the system can support condition monitoring and remote service.
When steam consumption varies, the control system can adjust capacity and regulate steam pressure. This makes it possible to maintain stable process pressure without unnecessarily high power.
We also clarify how the steam system should communicate with the customer’s PLC, supervisory control system, or other automation system. This may include start/stop signals, load control, alarm exchange, and central monitoring.
Steam boilers for larger industrial capacities
As standard, the boilers cover capacities from 250 to 10,000 kg of steam per hour and pressures from 2 to 16 bar. This makes them relevant for larger process plants, central steam supplies, and production with high and continuous steam consumption.
Steam is produced using electric flanged immersion heaters, which are mounted directly in the boiler vessel. The solution is sized according to the required steam output, operating pressure, water quality, voltage, and process load.
The boilers are supplied to the customer’s technical requirements. Design and manufacture can be carried out in accordance with PED 2014/68/EU or ASME Section VIII Division 1, depending on the project location and documentation requirements.
Complete skid-mounted steam systems
The larger steam boilers can be supplied as complete skid-mounted systems. A complete solution may include a steam boiler, feedwater tank, water treatment, and control panel. Piping and electrical cabling between components are completed at the factory, so the system arrives as a single unit and ready for installation.
The prefabricated design reduces the number of interfaces at the installation site.
The control panel can be supplied with system visualisation and communication options to existing automation or building management systems. The system is adapted, among other things, to voltage level, capacity, available space, and the customer’s requirements for data exchange.
Industrial steam, clean steam, and special requirements
Steam quality must match the specific process. For standard indirect heating, industrial steam may be sufficient. For processes where the steam comes closer to the product, there may be stricter requirements for materials, water quality, and the boiler design.
The compact steam generators can be supplied in stainless-steel versions for, among other things, clean steam applications. Here, the water- and steam-wetted components are made of stainless steel. The final selection should always be based on the process and the applicable hygiene and documentation requirements.
If clean steam or special steam is required, the solution must be assessed separately. Clean steam is not necessarily the same as standard process steam from a boiler in stainless-steel execution.
Water quality and feedwater treatment
Water quality is critical to the steam boiler’s operation, service life, and steam production. Hardness, salts, oxygen, and other impurities can lead to scale deposits, corrosion, and reduced heat transfer.
Therefore, the feedwater must be analysed, and the necessary treatment must be defined as part of the project. Depending on the raw water and process requirements, the system may require softening, reverse osmosis, chemical treatment, or other forms of water treatment.
The feedwater tank, condensate return, and blowdown will also be included in the assessment. A high proportion of returned condensate can reduce the need for new treated water and the energy used to heat the feedwater.
Correct sizing of an electric steam boiler
A steam boiler should not be selected solely based on maximum steam consumption. The load profile is critical to the right configuration. A system with a stable base load has different requirements than a process with short, high peak loads.
We assess, among other things, normal and maximum steam demand, operating pressure, start-up time, simultaneity, and expected operating hours. In addition, voltage, available power, space conditions, and options for future expansion are clarified.
With fluctuating demand, a modular solution can provide flexible capacity control and redundancy. With high and stable consumption, a larger central steam boiler may be the most appropriate solution.
From process data to a complete steam system
Newtronic advises on the entire steam system—not only the boiler itself. We help translate process requirements into a solution with the correct capacity, pressure, water treatment, control, and safety.
The delivery may include a steam boiler, feedwater module, control panel, documentation, installation, and commissioning. We can also assist with service and technical support after delivery.
Do you need electric process steam? Send us information about steam capacity, operating pressure, operating time, and application, and we will assess whether a modular steam generator or a larger Ecotherm steam boiler is the best fit for the process.
FAQ
It depends on the boiler type and the available electrical power. Compact electric steam generators can deliver from approx. 10 kg of steam per hour and can be combined in a cascade for higher capacities. For larger industrial steam demands, electric steam boilers are available with capacities up to approx. 10,000 kg of steam per hour. The correct size also depends on operating pressure and load profile.
Compact electric steam generators can be ready for full steam production in around 3 to 5 minutes. This makes them particularly attractive for processes with intermittent or fluctuating steam demand, where the boiler does not need to be kept warm continuously. Larger industrial steam boilers have a different start-up profile depending on boiler size and plant design.
A compact steam generator is typically suitable for smaller or fluctuating steam demands and can be installed close to the process. Multiple units can be connected if capacity needs to be increased. A larger electric steam boiler is typically relevant for continuous central steam supply and high capacities. The choice therefore depends primarily on steam consumption, load profile, pressure, and installation conditions.
Water quality is crucial for service life and operational reliability. Limescale, salts, oxygen and other impurities can cause deposits, corrosion and reduced heat transfer. The feedwater should therefore be analysed, and there may be a need for, for example, softening, reverse osmosis or other water treatment depending on the raw water and the boiler plant.
Industrial steam is typically used for indirect heating and standard industrial processes. For culinary applications, where the steam may come closer to the product, stricter requirements apply, including to materials and water quality. Pure steam imposes additional requirements and is not automatically the same as steam from a standard stainless steel steam boiler. The required steam quality must therefore be defined based on the process.