Electric hot water boilers from Värmebaronen
Downloads
Hot water boilers for industry and hydronic heating systems
Electric hot water boilers convert electrical energy directly into heat in a hydronic system. They are relevant when industry, the utilities sector, or larger properties need a controllable heat source without local combustion.
At Newtronic, we supply hot water boilers from Sweden’s Värmebaronen. As the Danish distributor, we advise on boiler selection, sizing, and integration into the overall system. This applies both when establishing new heating systems and when electrifying existing solutions based on oil, gas, or other energy sources.
A Värmebaronen electric boiler can be used as a standalone heat source or combined with, for example, a heat pump, heat exchanger, and buffer tank. The boiler can also serve as a backup when the primary heat supply is out of operation, or as peak load during periods of high heat demand.
Värmebaronen EP G2 from 31 to 1,500 kW
Värmebaronen EP G2 is designed for larger hydronic heating systems and is supplied in an output range from 31 to 1,500 kW. Multiple electric boilers can be connected if the system requires higher total output, flexible load sharing, or redundancy. The series regulates output in 7, 15, or 30 steps depending on model and size.
Stepwise control provides a more stable supply temperature than a solution with few, large output steps. The built-in control system can also limit the boiler to a lower output step if the power supply or operating strategy requires it.
EP G2 measures energy consumption as standard. The boiler is also equipped with dry-boil protection and monitoring of the heating elements. Element monitoring detects phase imbalance and can warn of potential issues with the heating elements.
Compact electric boilers for lower output requirements
Värmebaronen’s range also includes smaller electric boilers and electric heating units. The compact models can be used as an individual heat source, as a supplement to a heat pump, or as backup in smaller hydronic systems.
EP 26E and EP 42E deliver approximately 26 and 42 kW, respectively. Output is regulated in seven steps, and the boilers can be controlled via an external signal. EK 15E is a compact 15 kW heating unit with seven output steps, while EK 13 delivers 13 kW distributed across three steps.
The choice between a compact electric boiler and the larger EP G2 series depends, among other things, on heat demand, system volume, temperature requirements, available electrical capacity, and the need for communication and monitoring.
Temperature, pressure, and voltage are adapted to the system
Värmebaronen EP G2 has a standard control range from 20 to 95 °C. Selected solutions can be supplied for 105 °C, and HT versions can be used at temperatures up to 150 °C. The specific model must be selected based on the system’s desired supply temperature, pressure, and application.
The standard version is approved for an operating pressure of 6 bar. For system pressures up to 40 bar, the boiler can be separated from the primary circuit with a correctly sized heat exchanger. This way, the electric boiler itself operates within its approved conditions, while the heat is transferred to the higher pressure level.
As standard, the boilers are manufactured for 400 V. Selected models and customer-specific solutions can be supplied for voltages up to 690 V. Voltage, supply capacity, cable dimensions, and protection must therefore be clarified early in the project.
Controls, communication, and external output control
An electric hot water boiler must be able to work with the rest of the energy system. EP G2 can be supplied with Modbus or BACnet, allowing temperature, pressure, alarms, and operating states to be exchanged with a PLC, supervisory control system, or building automation. The boiler can also be controlled via external signals so the output is adapted to the system’s current needs.
For processes requiring fast or precise control, Värmebaronen can supply boilers with Solid State Relay, SSR. This solution can switch the output steps at short intervals, providing tighter temperature control.
Direct Power Control, DPC, is developed for applications where output must be changed quickly. This may, for example, be in connection with grid balancing or industrial processes with rapid load changes. The choice between traditional step control, SSR, and DPC should be based on process requirements, grid connection, and the desired response time.
Electric boilers as primary heat, backup, and peak load
Hot water boilers from Värmebaronen can be part of several different operating strategies. In an industrial process, the electric boiler can be placed close to the heat demand and supply hot water directly to the process circuit. This can reduce the need for long pipe runs and make the heating system easier to manage.
In hybrid energy systems, the electric boiler can supplement a heat pump when the heat demand exceeds the heat pump’s capacity. This can make it possible to size the heat pump for the base load, while the electric boiler covers peak loads and serves as a reserve.
Electric boilers can also be used in district heating and other energy systems where surplus electricity is converted into heat. The heat can be used directly or stored in a buffer tank. Economic operation depends, among other things, on the electricity price, taxes and duties, connection conditions, operating hours, and the value of the alternative heat source.
Correct sizing of the hot water boiler
The right electric boiler is not selected solely based on maximum output. We also consider supply and return temperatures, flow, system volume, heat-up time, peak load, and the expected operating pattern. At the same time, the electrical installation must be able to handle the boiler’s output and the desired control method.
Water quality affects the service life of the heating elements and the operation of the entire system. Incorrect water quality can lead to deposits, corrosion, and reduced heat transfer. The requirements depend, among other things, on temperature, materials, and the system design. Therefore, water quality and any water treatment should be included in the design from the outset.
Danish advice and service for Värmebaronen electric boilers
Newtronic is the Danish distributor of Värmebaronen. We advise on the complete boiler solution, from the initial output calculation to model selection, control, and integration.
We can also assist with installation, controls, communication, commissioning, and subsequent service. This provides a single technical dialogue covering both the electric boiler, automation, and the system’s other interfaces.
Do you need an electric hot water boiler for process heating, district heating, backup, or peak load? Send us details on output, temperature, pressure, and operation, and we will size a suitable solution with Värmebaronen.
Experience an electric boiler in our Techcenter
Visit our Techcenter and experience a Värmebaronen electric boiler in operation. Here you can see functions, control, and operation up close and get answers to your technical questions.
Contact us to arrange a demonstration.
Related solutions
FAQ
Yes. An electric hot water boiler can supplement a heat pump during peak load or serve as backup if the heat pump is out of operation. This can make it possible to size the heat pump for the base load and let the electric boiler cover the periods when the heat demand is highest.
Standard solutions typically operate at temperatures up to 95°C. Selected models can be supplied for 105°C, and high-temperature versions can operate with supply temperatures up to 150°C. The required temperature must be assessed together with pressure, flow, and the rest of the heating system.
Yes. Multiple hot water boilers can be connected in a cascade if a higher total output is required. This can also be used to create flexible load sharing or redundancy. Värmebaronen’s EP G2 range spans from 31 to 1,500 kW per boiler.
Electricity consumption depends on the boiler’s output and how long it operates at the given load. A boiler of, for example, 500 kW running at full output for one hour uses approximately 500 kWh of electricity. In practice, the output is adjusted to match the heat demand, so actual consumption depends on operating time, temperature requirements, and the load profile.
Yes. The standard boilers operate at a maximum working pressure of 6 bar. If the rest of the heating system operates at a higher pressure, the electric boiler can be isolated from the system using a heat exchanger. This allows the solution to be used with system pressures of up to 40 bar, while the boiler itself continues to operate within its approved pressure class.