Customised control for heating element and process
Control panels for process heating must match the heating element, the process, and the overall plant precisely. That is why we always deliver a custom-designed solution, where power, temperature control, safety, and communication are sized as an integrated whole.
The panel can be supplied together with the heating element, so electrical connections, sensors, and safety functions are clarified from the outset.
Control panels for industrial
process heating
Safety tailored to the heating element
The safety functions are assessed as an integrated part of the control panel. Depending on the application, the control system may include overtemperature protection, safety disconnection, flow monitoring, level control, and monitoring of faults in the heating zones.
The process sensor is normally used for continuous temperature control. In many installations, a separate safety sensor or temperature limiter is also used, which disconnects the heating power in the event of an abnormal temperature.
The specific safety solution depends, among other things, on the heating element’s design, the medium, the flow, and the consequence of a fault.
PLC, HMI, and communication
Control panels for process heating can be integrated with an existing PLC, supervisory control system, or SCADA system. Integration can be implemented with analogue and digital signals or via communication such as Modbus, Profinet, or Ethernet, depending on requirements.
An HMI can give the operator access to temperatures, setpoints, alarms, power steps, and operating status. In more advanced plants, the PLC control can also handle sequences, heating profiles, multiple temperature zones, and data collection.
Communication is clarified early in the project so that signals, functions, and responsibility boundaries are defined before the control panel is produced.
A complete solution with heating element and control panel
When the heating element and control panel are sized as one complete process heating solution, the number of technical interfaces is reduced. This makes installation more straightforward and reduces the risk that power control, sensors, or safety functions do not match the heating element.
We can supply the heating element, control panel, temperature sensors, and relevant documentation as a complete solution. As required, we also assist with installation, commissioning, tuning, and service. The control panel can be supplied with diagrams, component lists, and a functional description adapted to the project’s documentation requirements.
Have the control panel sized for your process heating
Send us information about the heating element, power, voltage, temperature requirements, and the desired control function. We assess the overall solution and design a control panel that matches the heating element, the process, and your automation environment.
Products you may also be interested in
FAQ
Yes. The heating element, control panel, temperature sensors and safety functions can be sized as one complete process heating solution. This reduces the interfaces between the components and ensures that power control, sensors, regulation and safety are matched to the specific heating element and the process.
Yes, in many cases a new control panel can be adapted to an existing heating element or process plant. This requires information such as power, voltage, current, temperature sensors, existing safety functions, and the desired control method. The existing installation should therefore be reviewed before the panel is specified.
No. A smaller or simple heating process can often be controlled with a temperature controller and contactors, or with electronic power control. A PLC and HMI typically become relevant when the process requires multiple functions, sequences, alarms, data collection, or integration with the rest of the production plant.
Yes. In processes where the temperature must change according to a specific sequence or over time, the control system can be programmed for different temperature steps, setpoints, and heating profiles. This may, for example, be relevant for preheating, drying, or other processes where the temperature should not remain constant throughout the entire cycle.
It depends on the panel’s safety design. In process-critical installations, a separate safety sensor or temperature limiter can shut off the heating output independently of the normal process control. Depending on the process, the control system can also monitor, for example, flow, level, and faults in the heating zones.