HVAC and building automation

Sensors, automation and heating elements for HVAC

From the first measurement to warm air

A well-functioning HVAC system requires more than accurate sensors. Measurement, control, and the component that actually affects the temperature must work together.

We supply sensors, transmitters, room automation and electric heating solutions for HVAC, CTS and BMS systems. This includes, among other things, temperature, humidity, CO₂, pressure and airflow, as well as electric duct heaters and fan heaters.

We help select the solution based on the system’s function, signal type, air volume, temperature requirements and integration with the rest of the automation.

Rumtermostat med display og betjeningsknapper monteret på væggen

  What do you need to measure, control or heat?

An HVAC system consists of many functions. That is why we start from the task rather than a specific part number.

Temperature

Measurement in rooms, ducts, pipes, heating and cooling circuits, on surfaces or outdoors.

Humidity and condensation

Measurement of relative humidity and monitoring of dew point and condensation risk.

 

temperaturfølere til industri

Air quality

CO₂, VOC and other parameters for monitoring and demand-controlled ventilation.

Pressure and airflow

Differential pressure across filters, duct pressure, fan monitoring, and measurement or control of air volume.

Rooms and zones

Measurement, operation and control of temperature, ventilation, fan coils and other local functions.

Air heating

Electric duct heaters for heating supply air, reheat and temperature control in ventilation systems.

Control is only as good as the chain around it  

Correct measurement is crucial.

But measurement only creates value when the rest of the system responds correctly to it.

For example, a temperature sensor can detect that the supply air is too cold. The CTS system must then convert the measurement into a control signal, and the duct heater must deliver the required heating output.

 

That is why we look at the entire function:

  • What needs to be measured?
  • Where should it be measured?
  • Which signal should be used?
  • How should control be carried out?
  • What heating output is required?
  • How should the solution be integrated?

From room temperature to differential pressure

Room sensors

For temperature, humidity and air quality in, among other places, offices, institutions, production areas and other buildings.

The sensor can be simple or combined with multiple measurement parameters, a display and local operation.

Duct and insertion sensors

For measuring temperature and other parameters directly in the ventilation duct.

Design and insertion length are selected based on the duct, installation and the measurement point to be represented.

 

Outdoor sensors

For measuring outdoor temperature and climate data used, for example, for weather compensation and demand control.

Pressure and differential pressure

For filter monitoring, duct pressure, fans, airflow and pressure conditions between rooms and zones.

Sensors for water installations

Temperature measurement in heating and cooling circuits, pipes and other hydronic HVAC systems.

The solution can, among other things, be implemented as an insertion sensor, thermowell or strap-on sensor.

Which signal should the automation work with?

Passive sensor

A passive temperature sensor changes electrical resistance with temperature.

Typical sensor principles are:

PT100, PT1000, Ni1000 and NTC

They are used when the automation has a suitable input for the specific sensor characteristic.

Active transmitter

An active transmitter converts the measurement into a standard signal such as:

0–10 V or 4–20 mA

It is used, among other things, for temperature, humidity, pressure and other measurement parameters.

Digital communication

With digital solutions, multiple values can be transmitted from the same device.

This can, among other things, be done via:

Modbus or BACnet

This is particularly relevant for multi-sensors, room units and installations with close integration to CTS/BMS.

When the air needs to be heated

Electric air heating is a natural part of many HVAC systems.

We supply electric duct heaters for both circular and rectangular ventilation ducts, as well as solutions for smaller and larger air volumes.

 

 

 

They are used, among other things, for:

Kanalvarmelegemer til opvarmning af luften
  • Heating of supply air
  • Reheat
  • Zone heating
  • Temperature control
  • Ventilation units
  • Air handling units
  • Comfort ventilation
  • Technical and industrial air systems

Circular duct heaters

A compact solution for round ventilation ducts, where the heating element is installed directly in the duct system.

They are relevant for, among other things, supply air, reheat and local temperature control.

Depending on the solution, control can be integrated or handled by an external CTS/BMS system.

 

Rectangular duct heaters

For larger ducts, ventilation units and systems with higher air volumes and output requirements.

Here, the design, duct size, output and control can be adapted to the specific installation.

A duct heater is not selected based on output alone  

Air volume

How many m³/h must pass through the heating element?

Inlet temperature

How warm is the air before it reaches the heating element?

Desired outlet temperature

How much should the temperature be increased?

Duct size

Air velocity and physical geometry affect the choice of heating element.

Supply voltage and output

The heating element must match the electrical installation and the desired heating output.

Control

Should the output be controlled internally, via 0–10 V, an external controller, or directly from CTS/BMS?

Safety

Airflow and overtemperature protection must be considered as part of the overall function.

It is the interaction between these parameters that determines the right solution.

More than a sensor on the wall

A modern room unit can be both a measurement point and an operating unit.

Depending on the solution, the same unit can, for example, handle: Temperature, Relative humidity, CO₂, VOC, Presence, Setpoint, Fan speed, Operating mode

This allows the user to have local influence on the indoor climate, while CTS/BMS continues to handle overall control.

Rumtermostat med display og betjeningsknapper monteret på væggen

 

In more advanced solutions, room automation can be part of the control of, for example, fan coils, VAV dampers, heating and cooling.

From standard component to the solution that fits the system  

A large share of HVAC tasks can be solved with proven standard products.

But both sensors and heating elements may require adaptation.

On the sensor side, this may include:

  • Sensor length
  • Diameter
  • Cable length
  • Cable routing
  • Process connection
  • Measuring range
  • Response time
  • Signal type
  • Enclosure
  • On the heating side, this may include:

    • Duct format
    • Air volume
    • Output
    • Voltage
    • Control
    • Material
    • Installation
    • Temperature requirements

    That is why we can work with both standard products and solutions tailored to the specific HVAC installation.